RF Test Cables

Results: 594
Select Image Part # Mfr. Description Datasheet Availability Pricing (EUR) Filter the results in the table by unit price based on your quantity. Qty. RoHS Connector A Series Connector A Gender Connector B Series Connector B Gender Maximum Frequency Impedance Cable Length Cable Type Minimum Bend Radius Flex Cycles Mating Cycles Maximum VSWR Jacket Colour Cable Diameter Jacket Material Minimum Operating Temperature Maximum Operating Temperature Insertion Loss Velocity of Propagation Contact Material
Pasternack PE3C100071-100CM
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 100 CM Length Using PE-TC154A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 40 GHz 50 Ohms 100 cm PE-TC154A Coax 1.4:1 5.41 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100071-12
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 12 Inch Length Using PE-TC154A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 40 GHz 50 Ohms 12 in PE-TC154A Coax 1.4:1 5.41 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100071-150CM
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 150 CM Length Using PE-TC154A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 40 GHz 50 Ohms 150 cm PE-TC154A Coax 1.4:1 5.41 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100071-24
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 24 Inch Length Using PE-TC154A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 40 GHz 50 Ohms 24 in PE-TC154A Coax 1.4:1 5.41 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100071-36
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 36 Inch Length Using PE-TC154A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 40 GHz 50 Ohms 36 in PE-TC154A Coax 1.4:1 5.41 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100078-100CM
Pasternack RF Test Cables 2.4mm Female to 2.4mm Male Low Loss Test Cable 100 CM Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Plug (Male) 50 GHz 50 Ohms 100 cm PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100078-12
Pasternack RF Test Cables 2.4mm Female to 2.4mm Male Low Loss Test Cable 12 Inch Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Plug (Male) 50 GHz 50 Ohms 12 in PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100078-150CM
Pasternack RF Test Cables 2.4mm Female to 2.4mm Male Low Loss Test Cable 150 CM Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Plug (Male) 50 GHz 50 Ohms 150 cm PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100078-24
Pasternack RF Test Cables 2.4mm Female to 2.4mm Male Low Loss Test Cable 24 Inch Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Plug (Male) 50 GHz 50 Ohms 24 in PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100078-36
Pasternack RF Test Cables 2.4mm Female to 2.4mm Male Low Loss Test Cable 36 Inch Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Plug (Male) 50 GHz 50 Ohms 36 in PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100079-100CM
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 100 CM Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 50 GHz 50 Ohms 100 cm PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 100 C 77 % Copper
Pasternack PE3C100079-12
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 12 Inch Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 50 GHz 50 Ohms 12 in PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 100 C 77 % Copper
Pasternack PE3C100079-150CM
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 150 CM Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 50 GHz 50 Ohms 150 cm PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 100 C 77 % Copper
Pasternack PE3C100079-24
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 24 Inch Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 50 GHz 50 Ohms 24 in PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 100 C 77 % Copper
Pasternack PE3C100079-36
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 36 Inch Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 50 GHz 50 Ohms 36 in PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 100 C 77 % Copper
Pasternack PE3C100080-100CM
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 100 CM Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 50 GHz 50 Ohms 100 cm PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100080-12
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 12 Inch Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 50 GHz 50 Ohms 12 in PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100080-150CM
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 150 CM Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 50 GHz 50 Ohms 150 cm PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100080-24
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 24 Inch Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 50 GHz 50 Ohms 24 in PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100080-36
Pasternack RF Test Cables 2.4mm Female to 2.4mm Female Low Loss Test Cable 36 Inch Length Using PE-TC177A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
2.4 mm Jack (Female) 2.4 mm Jack (Female) 50 GHz 50 Ohms 36 in PE-TC177A Coax 24.89 mm 1.45:1 4.5 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100081-100CM
Pasternack RF Test Cables 1.85mm Male to 1.85mm Male Low Loss Test Cable 100 CM Length Using PE-TC142A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
1.85 mm Plug (Male) 1.85 mm Plug (Male) 67 GHz 50 Ohms 100 cm PE-TC142A Coax 24.89 mm 1.5:1 3.58 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100081-12
Pasternack RF Test Cables 1.85mm Male to 1.85mm Male Low Loss Test Cable 12 Inch Length Using PE-TC142A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
1.85 mm Plug (Male) 1.85 mm Plug (Male) 67 GHz 50 Ohms 12 in PE-TC142A Coax 24.89 mm 1.5:1 3.58 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100081-150CM
Pasternack RF Test Cables 1.85mm Male to 1.85mm Male Low Loss Test Cable 150 CM Length Using PE-TC142A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
1.85 mm Plug (Male) 1.85 mm Plug (Male) 67 GHz 50 Ohms 150 cm PE-TC142A Coax 24.89 mm 1.5:1 3.58 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100081-24
Pasternack RF Test Cables 1.85mm Male to 1.85mm Male Low Loss Test Cable 24 Inch Length Using PE-TC142A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
1.85 mm Plug (Male) 1.85 mm Plug (Male) 67 GHz 50 Ohms 24 in PE-TC142A Coax 24.89 mm 1.5:1 3.58 mm - 40 C + 85 C 77 % Copper
Pasternack PE3C100081-36
Pasternack RF Test Cables 1.85mm Male to 1.85mm Male Low Loss Test Cable 36 Inch Length Using PE-TC142A Coax Non-Stocked Lead-Time 2 Weeks
Min.: 1
Mult.: 1
1.85 mm Plug (Male) 1.85 mm Plug (Male) 67 GHz 50 Ohms 36 in PE-TC142A Coax 24.89 mm 1.5:1 3.58 mm - 40 C + 85 C 77 % Copper